Table 292: Looparound <strong>and</strong> Conference Test (#33) 4 of 4<br />

Error<br />

Code<br />

Port Diagnostic Test (#35)<br />

Port Diagnostic Test (#35)<br />

This <strong>test</strong> is also known as the Battery Feed Test.<br />

The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing,<br />

transmission, <strong>and</strong> balance. This <strong>test</strong> checks the signaling <strong>and</strong> switch hook capabilities of the<br />

battery feed chip by terminating the port, applying battery, <strong>and</strong> trying to detect a current.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● ADX16A-P (AUDIX Analog Line/Control Link)<br />

.<br />

Test<br />

Result<br />

● ALARM-PT (Alarm Port)<br />

Description / Recommendation<br />

PASS This port is functioning properly. If users are reporting troubles, examine<br />

the loop connections to the port.<br />

● AN-LN-PT (Analog Line Port)<br />

● ANL-16-L (16-Port Analog Line)<br />

● ANL-LINE (8-Port Analog Line)<br />

● DID-TRK (Direct Inward Dial Trunk)<br />

● MET-LINE (MET Line)<br />

● RANL-STA (Remote Analog Line (Station) Port)<br />

Table 293: Port Diagnostic Test (#35) 1 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4 of 4<br />

1 of 6<br />

Issue 5 May 2009 1125