DIG-LINE (Digital Line)<br />

or move voice terminal closer to the switch (in terms of feet of wire from the jack to the<br />

switch). If the problem still exists, replace the circuit pack. Once the problem is resolved, the<br />

alarm is retired after a predetermined amount of time.<br />

c. Error Type 1, Aux Data 1 - 20 occurs when at least 15 off-board problems with the link to<br />

the terminal have been detected. When an <strong>error</strong> with the link is detected, an on-board<br />

counter is incremented.<br />

The user could experience a noisy port or link. This is an off-board problem detected by<br />

the port circuit. Check for defective wiring, a defective voice terminal, or move voice<br />

terminal closer to the switch (in terms of feet of wire from the jack to the switch). If the<br />

problem still exists, replace the circuit pack. Once the problem is resolved, the alarm is<br />

retired after a predetermined amount of time.<br />

d. Error Type 18: the port in question is busied out by maintenance personnel. Use<br />

release port location to release the port from busyout.<br />

e. Error Type 130: the circuit pack or media module has been removed or has been insane for<br />

more than 21 minutes. To clear the <strong>error</strong>, reinsert or replace the circuit pack or media<br />

module.<br />

f. Error Type 257: problems transmitting to the voice terminal. This can be caused by<br />

defective wiring, which can cause varying degrees of problems on different types of sets.<br />

Sets such as the 7410 appear to be more susceptible to wiring problems than other sets.<br />

This is usually an on-board problem <strong>and</strong> can be ignored if no user complaints are received.<br />

g. Error Type 767: a favorable response was received from running the Digital Line Electronic<br />

Power Feed Test (#11). No action is necessary. This alarm is resolved with the passing of<br />

time.<br />

h. Error Type 769, Aux Data 40963: unfavorable response was received from the Digital Line<br />

Electronic Power Feed Test (#11). See the <strong>test</strong> for repair procedures.<br />

i. Error Type 769, Aux Data 40988: the EPF/PTC circuit has been turned off due to an<br />

overcurrent condition.<br />

For TN754 vintage 13 or earlier <strong>and</strong> TN413, the EPF circuit senses an overcurrent<br />

condition at the voice terminal. Check for a short in the wiring, a damaged jack, an<br />

incorrect type of voice terminal, or a defective voice terminal.<br />

For TN754 vintage 14 or later, TN754B <strong>and</strong> TN2136, the PTC will open if there is a short<br />

on the power line for 1/2 second or longer. The voice terminal is probably not operating<br />

properly. Unplug the voice terminal for 30 seconds <strong>and</strong> then plug it back in. If the voice<br />

terminal still does not operate, then check for a short in the wiring, a damaged jack, an<br />

incorrect type of voice terminal, or a defective voice terminal.<br />

Once the problem has been resolved, it may take up to 1 hour for the alarm to clear. If the<br />

problem cot be resolved by one of the previous steps, then replace the circuit pack or<br />

media module.<br />

j. Error Type 769, Aux Data 40989: the CM software sends an EPF query to the port board<br />

for a particular port. The board returns the failure message 40989. This <strong>error</strong> is caused if the<br />

board is busy on TN2224CP HV4 FV15. 40989 represents a message from the board that<br />

Issue 5 May 2009 327