Communication Manager Maintenance Object Repair Procedures<br />

ATM-EI-Related Comm<strong>and</strong>s<br />

The following comm<strong>and</strong>s can be helpful in resolving ATM-EI problems:<br />

Replacing an ATM-EI Circuit Pack<br />

St<strong>and</strong>ard Reliability<br />

1. Enter busyout atm pn# (this is service-affecting) on the SAT.<br />

2. Replace the ATM PNC circuit pack, <strong>and</strong> reconnect the fiber.<br />

3. Enter release atm pnc.<br />

4. Wait 2½ minutes for board insertion.<br />

5. Enter list sys-link to verify that the links are up.<br />

6. Enter <strong>test</strong> board location, <strong>and</strong> verify that every <strong>test</strong> passes.<br />

Duplex or High Reliability<br />

There is 1 ATM-EI circuit pack in each PN.<br />

1. Enter busyout atm pnc # on the SAT.<br />

Note: If<br />

add atm pnc list measurements atm<br />

busyout/release atm pnc remove atm pnc<br />

busyout/release board reset board<br />

change atm pnc (pnc duplication) status atm pnc<br />

display atm pnc status cabinet<br />

list atm oam-statistics status port-network<br />

list atm pnc <strong>test</strong> board<br />

2.<br />

Note:<br />

the ATM-EI is in a PN, this is service-affecting.<br />

Replace the circuit pack.<br />

3. Enter release atm pnc.<br />

4. Wait 2½ minutes for board insertion.<br />

5. Enter list sys-link to verify that the links are up.<br />

126 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers