Table 286: Conference Circuit Test (#7) 4 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Conference Circuit Test (#7)<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

DAT-LINE:<br />

1. Enter status data-module to determine if the port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

PE-BCHL:<br />

1. Enter status pri-endpoint extension to determine if the<br />

port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

WAE-PORT:<br />

1. Enter status access-endpoint extension to determine if the<br />

port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

For all other Maintenance Objects:<br />

1. Enter display port location to determine the trunk group/<br />

member number or station extension of the port.<br />

2. Enter status trunk or status station<br />

extension to determine the service state of the port. If the port is<br />

in use, wait until it is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT The <strong>test</strong> is not applicable for this port. This <strong>error</strong> can be ignored.<br />

1018 ABORT The <strong>test</strong> has been disabled by administration. This may be due to the<br />

ONS Ringer Application Test #48, which can be customer or terminal<br />

disturbing.<br />

1. To enable the <strong>test</strong> for a particular station, enter change station<br />

extension <strong>and</strong> set the Maintenance Tests field on the Station<br />

screen to y. Submit the screen.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4 of 7<br />

Issue 5 May 2009 1095

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!