Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 313: Tie Trunk Seizure Test (#73) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The<br />

trunk may be busy with a valid call.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the<br />

port. If the service state indicates that the port is in use, wait<br />

until the port is idle before re<strong>test</strong>ing.<br />

3. If the port status is active but the port is idle (no calls), then<br />

check the Error Log for Error Type 1025. See the Error Log<br />

table for a description of Error Type 1025 for this maintenance<br />

object. The port may be locked up. The far-end may not be<br />

releasing.<br />

4. If the port status is idle, then retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

1. Enter display trunk-group xx to determine the trunk<br />

group/member number of the port.<br />

2. Enter status trunk to determine the service state of the<br />

port. If the service state indicates that the port is in use, wait<br />

until the port is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT This <strong>test</strong> is not valid for this trunk translation. The trunk must be a<br />

wink-start or delay dial trunk <strong>and</strong> must be outgoing or 2-way for this<br />

<strong>test</strong> to run. For the TN2140, the trunk must also be<br />

continuous-seize-ack or discontinuous-seize-ack.<br />

1. Check trunk translation. If it is not a wink-start or delay dial<br />

trunk, this abort message should be ignored.<br />

1018 ABORT Test is disabled by administration.<br />

1. Verify that the Maintenance Tests field on the Trunk Group<br />

screen is n. To enable the <strong>test</strong>, enter change trunk-group<br />

x where x is the number of the trunk group to be <strong>test</strong>ed, <strong>and</strong><br />

enter y in the Maintenance Tests field.<br />