Table 483: CSU Equipment Loopback Test (#1210) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

CSU Equipment Loopback Test (#1210)<br />

1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out.<br />

1. Enter busyout board location to put all trunks or ports of the<br />

DS1 Interface circuit pack into the out-of-service state.<br />

2. Retry the comm<strong>and</strong>.<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system.<br />

Executing this <strong>test</strong> could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be <strong>test</strong>ed, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

Tone-Clock circuit with the following comm<strong>and</strong> sequence:<br />

1. disable synchronization-switch.<br />

2. set synchronization location.<br />

3. enable synchronization-switch.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1950 ABORT Another loopback/span <strong>test</strong> is already executing on the DS1 board or the<br />

board is in a network requested loopback mode (Line loopback or<br />

Payload loopback). The <strong>error</strong> log will indicate whether a Customer<br />

loopback jack <strong>test</strong>, Far CSU Loopback <strong>test</strong>, or the One-Way Span <strong>test</strong> is<br />

executing or if the board is in line loopback or payload loopback mode.<br />

Only one long-duration loopback/span <strong>test</strong> can be active at a given time.<br />

If a loopback/span <strong>test</strong> is already active, that <strong>test</strong> must be deactivated via<br />

<strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong> in order to<br />

run this <strong>test</strong>.<br />

1951 ABORT The CSU Equipment Loopback <strong>test</strong> could not be executed because the<br />

120A CSU module/T1 sync splitter was not physically installed. Physically<br />

connect the 120A CSU module/T1 sync splitter to the DS1 board on the<br />

back of the port carrier.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Check for board hyperactivity. See Hyperactive DS1/UDS1<br />

Interface Circuit Pack/Media Module.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 of 3<br />

Issue 5 May 2009 1581