Communication Manager Maintenance Object Repair Procedures<br />

AXA12-RS (AUDIX Reserve Slots)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

AXA12-RS NONE NONE TN568 12-port analog<br />

reserve slot<br />

ADX8D-RS NONE NONE TN568 8-port digital<br />

reserve slot<br />

AXD12-RS NONE NONE TN568 12-port digital<br />

reserve slot<br />

There are no <strong>test</strong>s associated with these MOs. Both <strong>test</strong> board <strong>and</strong> busyout board abort<br />

when either is attempted on a reserved slot. An <strong>error</strong> message indicates that the slot is<br />

associated with the circuit pack that the TN568 is emulating, but the requested operation is not<br />

valid. If there are <strong>error</strong>s logged against these MOs, see XXX-BD (Common Port Circuit Pack/<br />

Media Module).<br />

The TN568 circuit pack connects to the switch through a single slot in the backplane. However,<br />

the number of slots physically occupied by the circuit pack is supplied by the board when<br />

inserted. The TN568 is 2 slots wide: the functional slot <strong>and</strong> a reserve slot. The reserve (blank)<br />

slot to the left of the functional slot is a place holder on the switch <strong>and</strong> has no interaction with<br />

the switch.<br />

These MOs are place holders for the extra slot needed for the EMBEDDED AUDIX board. Each<br />

instance of these MOs represents a reserve slot associated with the respective circuit pack<br />

mode in which the TN568 (EMBEDDED AUDIX) is working. They are used for EMBEDDED<br />

AUDIX <strong>and</strong> emulation of respective port types.<br />

206 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers