DID-TRK (Direct Inward Dial Trunk)<br />

l. Error Type 513, Aux Data -57392: Loop current active, CO is not releasing trunk after PBX<br />

disconnect. Occurs when the PBX end drops first <strong>and</strong> the CO does not release the trunk<br />

within 4 minutes.<br />

1. Verify the interface to the network with a h<strong>and</strong> telephone set. If calls are placed<br />

correctly, then refer problem to the CO.<br />

2. If unable to place calls or this equipment is not available, check the status on port<br />

using status trunk. If active but not connected, disconnect bridging clips at the<br />

network interface. Check status on the trunk. If trunk went idle, then replace clips. If<br />

trunk is still active but unable to place calls, refer problem to the CO.<br />

m. Error Type 513, Aux Data 57393: Late CO trunk release occurs only after the occurrence<br />

of Error Type 513. The CO released the trunk 4 minutes after the PBX dropped the call. This<br />

event decrements the severity (<strong>error</strong> count) of Error Type 513, or may mean the problem<br />

related to Error Type 513 has been fixed.<br />

Verify that Error Type 513 does not occur again. Refer to Error 513.<br />

n. Error Type 1793: Incomplete Dial timer expired. Applies only to the TN459 <strong>and</strong> indicates a<br />

problem with incoming dialing stream. Refer the problem to the CO.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

NPE Crosstalk Test (#6) X ND<br />

Port Diagnostic Test (#35) X X ND<br />

Looparound <strong>and</strong> Conference Test (#33) X ND<br />

Port Audit And Update Test (#36) X X ND<br />

1. D = Destructive; ND = Nondestructive<br />