Table 390: Battery Holdover Hardware Verification Test (#311)<br />

Error<br />

Code<br />

1000<br />

2000<br />

2029<br />

2500<br />

Test<br />

Result<br />

Description/ Recommendation<br />

DS1 OPS Switchhook Inquiry Test (#312)<br />

DS1 OPS Switchhook Inquiry Test (#312)<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

Response to the <strong>test</strong> was not received within the allowed time.<br />

Internal system <strong>error</strong>.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The hardware vintage of the PN’s Maintenance circuit pack does not<br />

support battery holdover for all carriers.<br />

This failure indicates that the cabinet administration is set for battery<br />

holdover for all carriers.<br />

1. Verify cabinet administration. Make sure that the battery holdover<br />

feature is administered correctly, <strong>and</strong> that cabinet administration is<br />

not set for battery holdover for all carriers.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS The cabinet administration shows battery holdover for A carrier only. Also,<br />

the hardware vintage of the PN’s TN775D Maintenance board is correct.<br />

This <strong>test</strong> queries the switchhook state of the Off-Premises-Station in switch software. If the state<br />

in switch software disagrees with the state on the DS1 Interface circuit pack, then the state in<br />

the switch software is updated to match the state on the DS1 Interface circuit pack.<br />

This <strong>test</strong> runs on OPS-LINE (DS1 Off-Premises Station Line).<br />

Table 391: DS1 OPS Switchhook Inquiry Test (#312) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 3<br />

Issue 5 May 2009 1351