19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 440: SNI-BD Configuration Audit (#759) 2 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2306 ABORT The SNI circuit pack is not responding to <strong>test</strong> requests sent by software.<br />

1. Run <strong>test</strong> led switch-node for the switch node where this board<br />

resides to verify whether the LEDs on the board light.<br />

2. If the LEDs on the other boards in the carrier light, but the LEDs on<br />

this board do not light, run Test #760 using <strong>test</strong> board location<br />

long for the active SNC in this carrier. Wait 5 minutes <strong>and</strong> then try<br />

step 1 one more time. If the LEDs on this board still do not light,<br />

replace this board. Replacing an SNI may be service interrupting.<br />

See SNI-BD (SNI Circuit Pack) for the procedure for replacing an<br />

SNI.<br />

3. If none of the LEDs light for the boards in the same carrier as this<br />

board, fix any problems associated with the connectivity of this<br />

carrier to the server.<br />

a. Check list fiber-link to see the fiber connections to this<br />

carrier.<br />

b. Check the LEDs on every SNI <strong>and</strong> EI, <strong>and</strong> fix any fiber problems.<br />

c. Enter display <strong>error</strong>s, <strong>and</strong> follow the repair procedures for<br />

any EXP-INTF <strong>error</strong> entries associated with the controlling IPSI<br />

connected PN.<br />

d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,<br />

FIBER-LK, or SNI-PEER <strong>error</strong> entries.<br />

4. Follow the Switch Node Interface Manual Loopback Procedure to<br />

determine whether the circuit pack or the fiber connection is faulty.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1474 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!