Table 267: LED Condition/Tone-Clock Circuit States 2 of 2<br />

Condition Tone-Clock<br />

Circuit State<br />

S8700-series Fiber-PNC:“Jingle bells”<br />

green <strong>and</strong> yellow<br />

0.1 sec on, 0.2 sec off,<br />

0.1 sec on, 0.4 sec off,<br />

0.4 sec on, 0.4 sec off<br />

Double blink yellow<br />

0.3 sec on, 0.3 sec off,<br />

0.3 sec on, 2.4 sec off,<br />

Error log entries <strong>and</strong> recommended actions<br />

St<strong>and</strong>by Maintenance software is <strong>test</strong>ing the<br />

st<strong>and</strong>by circuit pack (the st<strong>and</strong>by<br />

Tone-Clock is providing tones).<br />

Active TN2312 or TN2182 has lost all external<br />

references <strong>and</strong> is in holdover mode.<br />

Other green <strong>and</strong> yellow patterns Active Maintenance software is <strong>test</strong>ing the<br />

active circuit pack.<br />

S8700-series Fiber-PNC: r<strong>and</strong>om<br />

yellow<br />

St<strong>and</strong>by If the circuit pack is a TN2182, the amber<br />

LED may come on <strong>and</strong> off intermittently<br />

as ETR-PTs on the board are used for<br />

tone-detection services.<br />

1. For a Tone-Clock in the master PN, the external source is a primary or secondary DS1 source, or a<br />

Stratum-3 clock. For a Tone-Clock in a slave PN, the external source is the Expansion Interface circuit<br />

pack.<br />

Table 268: TONE-BD Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

Explanation<br />

On/Off<br />

Board<br />

1002 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> tone-clock<br />

location<br />

1 (b) 0 Circuit pack removed<br />

or SAKI Sanity <strong>test</strong><br />

(#53)<br />

18 (c) 0 busyout<br />

tone-clock<br />

location<br />

MIN ON<br />

WRN OFF release tone-clock<br />

location<br />