Table 320: Modem Pool Conference Test (#97) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Modem Pool Conversion Resource Looparound Test (#98)<br />

Any FAIL The Network Processing Element (NPE) of the <strong>test</strong>ed port did not<br />

conference the tones correctly. This will cause noisy <strong>and</strong> unreliable<br />

connections.<br />

1. If the remaining ports are currently idle (amber LED is off), reset the<br />

circuit pack.<br />

2. Repeat the <strong>test</strong>. If the <strong>test</strong> fails again, replace the circuit pack.<br />

PASS The port can correctly conference multiple connections. User-reported<br />

troubles on this port should be investigated using other port <strong>test</strong>s <strong>and</strong> by<br />

examining station, trunk, or external wiring.<br />

Modem Pool Conversion Resource Looparound Test (#98)<br />

The Modem Pool Conversion Resource Looparound <strong>test</strong> is set up as follows:<br />

Figure 97: Modem Pool Conversion Resource Looparound<br />

DIGITAL<br />

PORT<br />

MAINTENANCE/<br />

TEST BOARD<br />

(TN771B)<br />

Description / Recommendation<br />

TS-A<br />

TS-B<br />

TN758 POOLED MODEM CIRCUIT PACK<br />

DIGITAL<br />

PORTION<br />

ANALOG<br />

PORTION<br />

MODEM POOL CONVERSION RESOURCE<br />

TS-C<br />

4 of 4<br />