Table 353: Speech Synthesis DSP Tone Test (#165)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Speech Synthesis DSP Tone Test (#165)<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port may<br />

be busy with a valid call. Wait until the port is idle (amber LED is off)<br />

before re<strong>test</strong>ing.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1001<br />

1002<br />

1003<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1021 ABORT The 440-Hz tone was not detected by the Tone Detector circuit <strong>and</strong><br />

inter-digit time-out has occurred on the Tone Detector circuit.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, verify that every Tone Detector circuit<br />

in the system is functioning correctly by checking the Error Log <strong>and</strong><br />

using <strong>test</strong> board location long. Replace any faulty circuit<br />

packs containing Tone Detector circuits, <strong>and</strong> repeat the <strong>test</strong>.<br />

3. If the <strong>test</strong> continues to abort, replace the Speech Synthesis circuit<br />

pack.<br />

2000<br />

2100<br />

ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

Any FAIL The 440-Hz tone was not detected by the Tone Detector circuits.<br />

1. If the <strong>test</strong> fails again, verify that every Tone Detector circuit in the<br />

system is functioning correctly by checking the Error Log <strong>and</strong> using<br />

<strong>test</strong> board location long. Replace any circuit packs<br />

containing faulty Tone Detector circuits, <strong>and</strong> repeat the <strong>test</strong>.<br />

2. If the <strong>test</strong> fails again, replace the Speech Synthesis circuit pack.<br />

PASS The 440-Hz tone has been detected correctly. User-reported troubles<br />

should be investigated using other <strong>test</strong>s <strong>and</strong> by verifying other ports on this<br />

circuit pack are working correctly.<br />