Error log entries <strong>and</strong> recommended actions<br />

Table 232: SNC-BD Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

SNC-BD (Switch Node Clock Circuit Pack)<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

1 (b) Any Failure audit (#777) MAJ ON <strong>test</strong> board location<br />

18 (c) 0 busyout board location WRN OFF release board location<br />

257 (d) Any Failure audit (#777) MAJ OFF <strong>test</strong> board location<br />

513 (e) Any Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

769 (f) Any Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1025 (g) Any Failure audit (#777) MAJ ON <strong>test</strong> board location<br />

1281 (h) Any Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1537 (i) Any Failure audit (#777) MIN ON <strong>test</strong> board location<br />

1793 (j) Any Failure audit (#777) MAJ ON <strong>test</strong> board location<br />

2049 (k) Any Failure audit (#777) MAJ ON <strong>test</strong> board location<br />

6008 (l) 0 SNC Release/Busy<br />

(#781)<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: SNC on-board microcontroller <strong>error</strong>. Replace the SNC circuit pack.<br />

c. Error Type 18: the SNC circuit pack was busied out using busyout board location. To<br />

resolve this <strong>error</strong>, use release board location to release the SNC circuit pack.<br />

d. Error Type 257: firmware detects failure of the phase-locked loop, inability to lock, or failure<br />

of the clock drivers. The problem is off-board.<br />

1. Enter display <strong>error</strong>s. If SNC-BD Error Type 1793 exists in the <strong>error</strong> log, follow the<br />

repair procedures for SNC-BD Error Type 1793.<br />

2. Enter display <strong>error</strong>s. If no SNI-BD 1025 <strong>error</strong>s exist in the <strong>error</strong> log, replace the<br />

active SNC.<br />

3. Enter display <strong>error</strong>s. If any SNI-BD 1025 <strong>error</strong>s exist in the <strong>error</strong> log, follow the<br />

repair procedure in SNI-BD (SNI Circuit Pack) for these <strong>error</strong>s.<br />