Table 215: PPP-PT Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

1 (b) 0 SCOTCH Sync<br />

Looparound<br />

(#1275)<br />

257 (c) 0 WRN OFF<br />

513 (d) 0 MIN OFF<br />

769 (e) 0 WRN OFF<br />

1281 (f) 0<br />

1537-8 (g) See<br />

note<br />

1793 to<br />

1920 (h)<br />

2305 to<br />

2816 (i)<br />

See<br />

note<br />

See<br />

note<br />

Associated Test Alarm<br />

Level<br />

Session Status<br />

<strong>test</strong> (#1286)<br />

3329 (j) 35768 TCP/IP Ping <strong>test</strong><br />

(#1281)<br />

3585 (k) 0, 1 TDM Looparound<br />

(#1285)<br />

On/Off<br />

Board<br />

MIN ON <strong>test</strong> port location l r 3<br />

MIN OFF<br />

Recommended Action<br />

MIN OFF <strong>test</strong> port location r 3<br />

WRN1 MAJ ON <strong>test</strong> port location l r 3<br />

1. Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 1: SCOTCH Synchronous Looparound <strong>test</strong> (#1275) failed.<br />

1. Test the port (<strong>test</strong> port location long).<br />

2. See SCOTCH Synchronous Looparound Test (#1275) for repair procedures.<br />

c. Error Type 257: C-LAN port detected overrun or underrun condition that may indicate a<br />

hardware problem.<br />

1. Test for hardware problem (<strong>test</strong> port location long).<br />

2. See SCOTCH Synchronous Looparound Test (#1275) for repair procedures to verify<br />

repair.<br />

3. Clear the alarm (<strong>test</strong> port location long clear).<br />

784 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />