● If the system synchronization reference is a DS1 interface circuit pack <strong>and</strong> the<br />

master Tone-Clock circuit pack fails TDM Bus Clock Test #150, the primary or<br />

secondary (if administered) synchronization references are not providing valid<br />

timing signals for the system. Check the system synchronization references<br />

administered, <strong>and</strong> follow the steps outlined in note (a) if the primary<br />

synchronization reference is providing timing for the system or note (c) if the<br />

secondary synchronization reference is providing timing for the system.<br />

● If the slave Tone-Clock circuit pack fails the TDM Bus Clock Test #150 but the<br />

master Tone-Clock does not fail this <strong>test</strong>, the master Tone-Clock circuit pack must<br />

be replaced.<br />

If SLIP <strong>error</strong>s remain follow SLIP ANALYSIS.<br />

3. Error 2305:<br />

● If the problem persists, replace the Tone-Clock circuit pack in the slave port<br />

network. Follow the steps listed in TDM-CLK (TDM Bus Clock) to replace the<br />

Tone-Clock circuit pack.<br />

g. Noise on the DS1 line can cause transient alarms on synchronization. Therefore, when a<br />

synchronization problem occurs causing Error Types 1, 257, or 513, a WRN alarm is first<br />

raised for 15 to 20 minutes before the alarm is upgraded to a MAJOR or MINOR alarm.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

S8700-series Fiber-PNC: If Stratum 3 is administered using change synchronization, the<br />

Stratum-3 Clock Alarm Query (#649) also executes when <strong>test</strong> synchronization is run.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

924 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND<br />

Synchronization Update Test (#417) X X Non-Destructive