Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 346: TDM Bus Clock Circuit Status Inquiry Test (#148) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

66 FAIL There is an on-board failure of TDM clock hardware.<br />

1. Enter <strong>test</strong> tone location long to resolve the problem. The<br />

long <strong>test</strong> resets the board <strong>and</strong> is required to reload on-board RAM<br />

associated with the TN2182’s DSPs. The effect is that tone<br />

detectors are taken out of service momentarily <strong>and</strong> tones are<br />

removed from the TDM bus for about 10 seconds. This means that<br />

no dial tone or touch tones are available during this interval. It<br />

probably will not affect calls in progress, but could cause a call<br />

origination to abort or a user will not get dial tone when going<br />

off-hook.<br />

2. If the <strong>test</strong> passes <strong>and</strong> the alarm does not resolve, re<strong>test</strong> with<br />

<strong>test</strong> tone-clock location long clear.<br />

3. If the <strong>test</strong> passes, the repair process is completed. If the <strong>test</strong> fails,<br />

replace the circuit pack at the customer’s convenience.<br />

PASS TDM bus Clock Circuit Status is sane. There are no clock-detection<br />

circuit problems on the Tone-Clock circuit.<br />

TDM Bus Clock Slip Inquiry Test (#149)<br />

This <strong>test</strong> queries the Tone-Clock circuit pack for timing slips.<br />

This <strong>test</strong> is not applicable for TN2182, TN2312, or TN8412 circuit packs.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />