SPID Facility Test<br />

BRI-SET, Various Adjuncts<br />

This <strong>test</strong> verifies the wiring <strong>and</strong> operation of the signaling link between the switch <strong>and</strong> a<br />

endpoint or adjunct on a BRI interface. This <strong>test</strong> is not executed from the administration<br />

terminal, but rather is executed by using a BRI <strong>test</strong> set equipped with a display. The <strong>test</strong> set<br />

may replace the BRI set, ASAI or <strong>Avaya</strong> adjunct under <strong>test</strong> by plugging it into the same jack or<br />

by bridging it onto the wiring at some point between the switch <strong>and</strong> the endpoint (or adjunct),<br />

thereby creating a pseudo-BRI multipoint configuration.<br />

When plugged into the port in this mer, the <strong>test</strong> set establishes a signaling link connection with<br />

the switch <strong>and</strong> attempts to complete Service Profile IDentifier (SPID) initialization by using the<br />

Service SPID administered for the system (see the System Maintenance Administration<br />

screen). If the <strong>test</strong> set displays the correct administered port address for the endpoint or adjunct<br />

under <strong>test</strong>, the <strong>test</strong> passes (see Table 63: Service SPID Display). If after one minute nothing is<br />

displayed on the <strong>test</strong> set, the <strong>test</strong> fails.<br />

Table 62: SPID Facility Test 1 of 2<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL No response is received from the endpoint.<br />

1. Check the physical wiring between the switch <strong>and</strong> the endpoint or adjunct.<br />

2. If <strong>test</strong> continues to fail, escalate the problem.<br />

FAIL Display does not match administered port address for the endpoint or adjunct.<br />

1. Change station administration for endpoint or adjunct to match displayed port<br />

address.<br />

2. If <strong>test</strong> continues to fail, escalate the problem.<br />

1 of 2<br />

Issue 5 May 2009 233