Table 484: CSU Repeater Loopback Test (#1211) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

CPE Loopback Jack Test (#1212)<br />

CPE Loopback Jack Test (#1212)<br />

PASS The RLB <strong>test</strong> executed successfully. The <strong>test</strong> pattern was transmitted <strong>and</strong><br />

received successfully over the connection from the DS1 board to the<br />

far-edge of the 120A CSU module/T1 sync splitter.<br />

1. Enter release board location to release the trunks or ports.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures<br />

3 of 3<br />

This <strong>test</strong> is destructive.<br />

For documentation purposes, the term DS1 applies to the following:<br />

DS1 Interface circuit packs<br />

DS1 Interface media modules<br />

UDS1 circuit packs.<br />

The CPE Loopback Jack (CLJ-LB) <strong>test</strong> causes a loopback at the CPE loopback jack <strong>and</strong> <strong>test</strong>s<br />

the building wiring connection between the DS1 board <strong>and</strong> the CPE loopback jack.<br />

The <strong>test</strong> is highly destructive <strong>and</strong> can only be initiated by entering the comm<strong>and</strong><br />

<strong>test</strong> ds1-loop location cpe-loopback-jack-<strong>test</strong>-begin [number-of-bits<br />

bit-pattern]. Enter a loopback activation code on the comm<strong>and</strong> line or use the default code<br />

(0x47F).<br />

Enter busyout board to busy out all trunks or ports on the DS1 Interface circuit pack before<br />

running the CPE Loopback Jack <strong>test</strong>.<br />

The CPE Loopback Jack <strong>test</strong> has the DS1 Interface circuit pack transmit a loopback activation<br />

code to the CPE loopback jack, waits up to 10 seconds for return of the code to verify the<br />

loopback has been established, transmits a framed 3-in-24 <strong>test</strong> pattern, begins counting bit<br />

<strong>error</strong>s in the received <strong>test</strong> pattern, <strong>and</strong> returns a PASS result to indicate that the pattern was<br />

successfully sent. If the loopback is not established within the 10 seconds, the <strong>test</strong> returns FAIL.<br />

The status of the CPE Loopback Jack <strong>test</strong> appears in the <strong>error</strong> log as Error Type 3900. Several<br />

distinct aux values give information on the status of the <strong>test</strong>.<br />