TIME-DAY (Time of Day)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

TIME-DAY MIN set time Time of Day<br />

The time of day contains the current year, month, day of the week, day of the month, hour,<br />

minute, <strong>and</strong> second. The Time of Day MO monitors the time-of-day clock, <strong>and</strong> raises an alarm if<br />

the time-of-day clock is not set or cot be read by the software. If the time-of-day clock is not set<br />

or cot be read by the software, many features such as Time-of-Day Routing, CDR, ISDN<br />

Call-by-Call, <strong>and</strong> duplication, are inoperative or incorrect. Use set time to set the time-of-day<br />

clock when the system is initially powered up.<br />

Use display time to read the time-of-day clock. Use set time to set the time-of-day clock.<br />

The time-of-day clock has a backup battery to save the time of day during power failures.<br />

There are no dem<strong>and</strong> <strong>test</strong>s associated with TIME-DAY.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 265: TIME-DAY Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended<br />

Action<br />

0 0 Any Any Any display time<br />

247 (a) 0 MIN OFF set time<br />

Note:<br />

a. Error Type 247: software cot read the time-of-day clock. During this condition, every time<br />

stamp in the Alarm Log entry, Error Log entry, <strong>and</strong> Software Error Log entry is potentially<br />

inaccurate. In addition, any features that are sensitive to the time of day (such as SMDR,<br />

Time-of-Day Routing, ISDN Call-by-Call) will not function correctly.<br />

To resolve the alarm:<br />

1. Use set time to set the time of day.<br />

2. Use display time to display the time of day. If the time of day is displayed correctly,<br />

wait 15 minutes <strong>and</strong> verify that the alarm is retired.<br />

986 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers