Error log entries <strong>and</strong> recommended actions<br />

Table 138: HYB-LINE Error Log Entries<br />

Error Type Aux<br />

Data<br />

0 1<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 Any Any Any <strong>test</strong> port location<br />

1 (a) 40987 WRN OFF<br />

15 (b) Any Analog Line Audits<br />

<strong>test</strong> (#61)<br />

18 (c) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

130 (d) WRN ON <strong>test</strong> port location<br />

257 (e) 40988 MIN<br />

WRN<br />

OFF<br />

513 (f) 40965 Analog Line Audits<br />

<strong>test</strong> (#61)<br />

WRN OFF <strong>test</strong> port location r 4<br />

769 (g) Remote Digital<br />

Looparound (#59)<br />

WRN OFF <strong>test</strong> port location r 3<br />

1025 Hybrid Circuit &<br />

Conf. Circuit (#57)<br />

1281(g) (h) Local Digital<br />

Looparound (#58)<br />

MIN<br />

WRN<br />

1537 (h) (i) 40968 WRN OFF<br />

1793 NPE Crosstalk<br />

Test (#6)<br />

2049 (i) (j) 32770<br />

2049 (j) 40967<br />

ON <strong>test</strong> port location l r 3<br />

WRN ON <strong>test</strong> port location l r 3<br />

MIN<br />

WRN 2<br />

ON <strong>test</strong> port location l r<br />

1. Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong> sequence. Refer to each appropriate<br />

<strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

2. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options<br />

comm<strong>and</strong>.<br />

504 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers