Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on TIE-TRK (Analog Tie Trunk).<br />

Table 314: Tie Trunk EPF Test (#74) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The trunk<br />

may be busy with a valid call.<br />

1. Enter display trunk-group xx to determine trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port is<br />

idle before re<strong>test</strong>ing.<br />

3. If the port status is active, but the port is idle (no calls), check the<br />

Error Log for Error Type 1025. See the Error Log table for the<br />

description of this <strong>error</strong> <strong>and</strong> required actions for this maintenance<br />

object. The port may be locked up. The far-end may not be<br />

releasing.<br />

4. If the port status is idle, then retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

1. Enter display trunk-group xx to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port is<br />

idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT This <strong>test</strong> is not valid for this trunk translation. Must be a type-1 st<strong>and</strong>ard<br />

trunk for this <strong>test</strong> to run.<br />

1. Check trunk configuration. If it is not a type-1 st<strong>and</strong>ard trunk, this<br />

<strong>error</strong> can be ignored.<br />

1178 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />