Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

6. Run <strong>test</strong> led port-network on the port network connected to the distant switch<br />

node, <strong>and</strong> verify that the LEDs on the correct PN are lit.<br />

7. Repeat steps 4 – 6 until every SNI-to-SNI fiber connection to the distant switch has been<br />

<strong>test</strong>ed.<br />

FIBER-LK Error <strong>codes</strong> <strong>and</strong> recommended actions<br />

The following table contains the <strong>error</strong> <strong>codes</strong> <strong>and</strong> recommended actions for FIBER-LK (Fiber<br />

Link).<br />

Table 438: FIBER-LK Configuration Audit (#759) 1 of 10<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

2300 The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

2301 The timer could not be set before sending the downlink message.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1460 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 10