Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● SNI-PEER (SNI Peer Link)<br />

Table 436: SNI Destructive Facility Off-Board Test (#756) 1 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1015 ABORT FIBER-LK: This <strong>test</strong> cot run because the fiber link has not been busied<br />

out. Busyout the fiber link with busyout fiber-link F P, then enter<br />

<strong>test</strong> fiber-link F P long.<br />

SNI-BD: The <strong>test</strong> cot run because the SNI circuit pack has not been<br />

busied out. Enter busyout board location to busyout the SNI<br />

circuit pack, then enter <strong>test</strong> board location long.<br />

1415<br />

1416<br />

ABORT The lightwave transceiver is absent from Endpoint 1 of the fiber link.<br />

The lightwave transceiver is absent from Endpoint 2 of the fiber link.<br />

1. If a lightwave transceiver should not be present, do nothing. For<br />

example, an SNI connected to a DS1 converter circuit pack or an<br />

SNI with a metallic connection does not have a lightwave<br />

transceiver. This <strong>test</strong> can only be run when a lightwave transceiver<br />

exists.<br />

2. Enter list fiber-link to display fiber link endpoints.<br />

3. Check the lightwave transceiver connections.<br />

4. Replace the lightwave transceiver. If a fiber out-of-frame condition<br />

exists <strong>and</strong> lightwave transceivers are used, check that the lightwave<br />

transceivers are of the same type (both are 9823a or both are<br />

9823b). If they are not the same type, replace one of the lightwave<br />

transceivers:<br />

● 9823a is used for distances up to 4900 feet.<br />

● 9823b is used for distances up to 25,000 feet.<br />

5. Replace the SNI circuit pack.<br />

1450 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />