Table 264: TIE-TRK Error Log Entries 2 of 2<br />

Error<br />

Type<br />

1025 (n) Any None MAJ<br />

MIN<br />

WRN 1<br />

1281 (m) Any EPF M <strong>and</strong> E Lead<br />

(#74)<br />

1537 Looparound <strong>and</strong><br />

Conference (#33)<br />

1793 Tie Trunk Seizure<br />

(#73)<br />

Dial Test #747 for<br />

TN439<br />

MAJ<br />

MIN<br />

WRN 1<br />

MAJ<br />

MIN<br />

WRN 1<br />

MAJ<br />

MIN<br />

WRN 1<br />

2049 NPE Crosstalk (#6) MAJ<br />

MIN<br />

WRN 1<br />

2305 (o) 57424<br />

50944<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

982 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

OFF<br />

2561 (p) 0 WRN OFF<br />

2562 (q) 16665<br />

2817 (p) 0 MIN OFF<br />

2817 (r) 52992<br />

3073 (p) 0<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

3840 (s) 8000 Transmission <strong>test</strong>s<br />

(ATMS) (#844–848)<br />

3841 (s) Transmission <strong>test</strong>s<br />

(ATMS) (#844–848)<br />

On/Off<br />

Board<br />

Recommended Action<br />

ON <strong>test</strong> port location r 3<br />

ON <strong>test</strong> port location l r 3<br />

OFF <strong>test</strong> port location r 2<br />

ON <strong>test</strong> port location l r 3<br />

OFF <strong>test</strong> analog-<strong>test</strong>call<br />

MIN OFF <strong>test</strong> analog-<strong>test</strong>call<br />

location r 2<br />

1. Minor alarms on this MO may be downgraded to Warning based on the values used in set<br />

options. If the MINOR alarm is not downgraded, the MINOR alarm is upgraded to a MAJOR<br />

alarm if 75% of the trunks in this trunk group are alarmed. These <strong>error</strong>s, if applicable, always<br />

log a MINOR alarm for TN439 <strong>and</strong> TN497.<br />