CO Port Diagnostic Test (#3)<br />

CO Port Diagnostic Test (#3)<br />

For ground start trunks, circuit pack or media module port relays are operated <strong>and</strong> checked to<br />

see if the port can detect <strong>and</strong> apply ground on the Tip lead. This <strong>test</strong> also verifies that there is no<br />

external ground on the Ring lead. In the absence of other failures, the circuit pack or media<br />

module should be replaced only if this <strong>test</strong> fails with the CO line disconnected.<br />

This <strong>test</strong> also checks the on-board programmable transmission circuits that allow the circuit<br />

pack or media module to support transmission characteristics of several different countries.<br />

This <strong>test</strong> runs on CO-TRK (Analog CO Trunk) <strong>and</strong> DIOD-TRK (DIOD Trunk).<br />

Table 283: CO Port Diagnostic Test (#3) 1 of 2<br />

Error<br />

Code<br />

1000<br />

1004<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

The port may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port<br />

is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT Test is not valid for the present configuration. This <strong>error</strong> can be ignored.<br />

1018 ABORT Test has been disabled by administration. Determine why this <strong>test</strong> was<br />

disabled before enabling it.<br />

1. To enable the <strong>test</strong>, enter change trunk-group <strong>and</strong><br />

enter y in the Maintenance Tests field on the Trunk Group form.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 2<br />