Table 346: TDM Bus Clock Circuit Status Inquiry Test (#148) 2 of 3<br />

Error<br />

Code<br />

4<br />

8<br />

16<br />

32<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The local oscillator on the Tone-Clock circuit failed.<br />

TDM Bus Clock Circuit Status Inquiry Test (#148)<br />

FAIL The circuitry which detects synchronization timing <strong>error</strong>s on the<br />

Processor/Tone-Clock circuit has failed.<br />

1. Errors 2, 4, 8, 16, <strong>and</strong> 32 indicate that there is poor<br />

synchronization between port networks <strong>and</strong> external facilities. It<br />

may be noticeable to the customer in the form of <strong>error</strong>s in data<br />

communications. The Tone-Clock circuit is defective. See<br />

Replacing the IPSI or Tone-Clock Circuit Pack.<br />

64 FAIL There has been a loss of valid synchronization timing information<br />

coming into this port network. It has been reported as TDM-CLK Error<br />

Log entries with one or more of Error Types 1025, 1281, 1537, 2049<br />

<strong>and</strong> 2305.<br />

1. Resolve the <strong>error</strong>s indicated for TDM-CLK (TDM Bus Clock). No<br />

separate corrective action is required.<br />

65 FAIL The Processor/Tone-clock is currently not able to lock on to the current<br />

synchronization reference. If this tone-clock is in the master port<br />

networK:<br />

1. Examine the <strong>error</strong> log for any DS1-BD, SYNC or other TDM-CLK<br />

<strong>error</strong>s <strong>and</strong> resolve as applicable.<br />

2. Run this <strong>test</strong> again using <strong>test</strong> tone-clock location.<br />

3. Examine the DS1 measurements to determine whether the facility<br />

is healthy.<br />

4. Administer a new synchronization reference.<br />

5. Replace the DS1 board currently supplying the reference.<br />

If this tone-clock is in the slave port network:<br />

6. Examine the <strong>error</strong> log for any SYNC, EXP-INTF, or TDM-CLK<br />

<strong>error</strong>s.<br />

7. Run this <strong>test</strong> again with <strong>test</strong> tone-clock location.<br />