Table 287: GPP NPE Crosstalk Test (#9) 1 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

GPP NPE Crosstalk Test (#9)<br />

1 ABORT During <strong>test</strong>ing of the primary information chel, system resources may<br />

not have been available or the port may have been busy during the <strong>test</strong>.<br />

1. Enter display port location to determine the extension of<br />

the port.<br />

2. Enter status station extension to determine the service<br />

state of the port. If the service state indicates that the port is in use,<br />

wait until it is idle.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 ABORT System resources may not have been available or the port may have<br />

been busy during the <strong>test</strong>.<br />

DIG-LINE <strong>and</strong> E-DIG-ST:<br />

1. Check if port is being used. If possible, disconnect by toggling the<br />

disconnect button on DTDM. Retry the comm<strong>and</strong> after 1 minute.<br />

WARNING: This action will drop any calls in progress.<br />

All other Maintenance Objects:<br />

1. Verify that the port is idle.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 6<br />

Issue 5 May 2009 1099