Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 461: Packet Interface Read <strong>and</strong> Clear Counters Test (#887) 2 of 4<br />

Error<br />

Code<br />

256<br />

512<br />

768<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The active IPSI circuit pack’s Packet Interface module has an <strong>error</strong><br />

counter set. The following Error Codes are possible: 256 (parity <strong>error</strong>),<br />

512 (FIFO overflow), 768 (parity <strong>error</strong> <strong>and</strong> FIFO overflow <strong>error</strong>).<br />

1. This may be the result of old firmware not supporting new<br />

software operation. Verify the IPSI circuit pack’s firmware vintage<br />

<strong>and</strong> download the new firmware if appropriate.<br />

2. The firmware image on the IPSI circuit pack may have been<br />

corrupted. Download the firmware image.<br />

3. Retry the comm<strong>and</strong>.<br />

4. If the same Error Code occurs, <strong>and</strong> Error Code 256 or 768 is<br />

reported, the IPSI’s Packet Interface module received a parity<br />

<strong>error</strong> off the packet bus.<br />

a. Check for alarms logged against the packet bus. See<br />

PKT-BUS (Packet Bus) to clear those <strong>error</strong>s first.<br />

b. Check for alarms <strong>and</strong> <strong>error</strong>s logged against other circuit<br />

packs connected to the PN’s packet bus. See Maintenance<br />

Object Interactions for a list of packet circuit packs. Refer to<br />

the repair procedures for those circuit packs to clear those<br />

<strong>error</strong>s first.<br />

c. S8700-series Fiber-PNC: If this is a st<strong>and</strong>ard- or duplex-reliability<br />

system, replace the IPSI circuit pack at a time that would<br />

cause the least disruption of service. The circuit pack is still<br />

functional but should be replaced.<br />

d. If this is a high-reliability (S8700-series Fiber-PNC: or<br />

critical-reliability) system <strong>and</strong> if the Packet Interface module<br />

is on the st<strong>and</strong>by IPSI, replace the st<strong>and</strong>by IPSI circuit pack.<br />

e. If this is a high-reliability (S8700-series Fiber-PNC: or<br />

critical-reliability) system <strong>and</strong> if the Packet Interface module<br />

is on the active IPSI, enter set ipserver-interface to<br />

perform a pled IPSI interchange. Replace the st<strong>and</strong>by IPSI<br />

circuit pack.<br />

1534 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />