Programmable Terminals<br />

The following parameters are downloaded to programmable terminals.<br />

Table 85: Parameters Downloadable to Programmable Terminals<br />

Nonvolatile Memory<br />

Nonvolatile memory stores downloadable parameters in programmable terminals. Once the<br />

terminal is downloaded, it is not be necessary to download it again, even if power is removed<br />

from the terminal. If nonvolatile memory fails with power still present, the terminal reverts to its<br />

default factory settings except for its A-law/mu-law comp<strong>and</strong>ing settings which are stored in<br />

RAM. If power is removed after the nonvolatile memory fails, the terminal reverts to its factory<br />

default settings.<br />

Note: The<br />

Parameter Scope Terminal<br />

International Flags (A-law/mu-law,<br />

Display Mode, DLI Voltage level)<br />

System level 84xx, 603x, 302B1<br />

Primary Levels (Transmission & Sidetone) System level 84xx, 603x, 302B1<br />

Adjunct Levels (Transmission & Sidetone) System level 84xx<br />

H<strong>and</strong>set Exp<strong>and</strong>er Option System level 84xx<br />

Administrable Options<br />

(Speakerphone & Mute Button)<br />

Per-terminal 84xx<br />

Administrable Softkeys Per-terminal, System level 8410D, 8434D<br />

Note:<br />

mu-law comp<strong>and</strong>ing mode is assigned as a default setting at the factory. For<br />

the United States, a programmable terminal can place calls even though it has<br />

not been downloaded from the system.<br />

Download Actions<br />

There are several different scenarios that cause a terminal to be downloaded. These can occur<br />

as part of background maintenance activity or on dem<strong>and</strong> from the system access terminal or<br />

from a station.<br />

For the following background actions, the terminal downloads automatically if a download retry<br />

flag for the terminal is set in software. This flag is set:<br />

● At boot time when translation is loaded<br />

● When translation that affects the parameters of a terminal is changed as part of system<br />

administration action<br />

● When a port is inserted in software as a result of board insertion or translation change<br />