Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● DIOD-DS1 (DS1 DIOD Trunk)<br />

Table 392: DS1 CO Trunk Dial Tone Seizure Test (#314) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT The <strong>test</strong> was aborted because system resources required to run this<br />

<strong>test</strong> were not available. The port may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the port is in use, wait until it is idle before <strong>test</strong>ing.<br />

3. If the port status is active but the port is idle (no calls), check the<br />

<strong>error</strong> log for Error Type 1025. The port may be locked up.<br />

4. If the port status is idle, retry the comm<strong>and</strong> at 1-minute intervals up<br />

to 5 times.<br />

1004 ABORT The port was seized by a user for a valid call during the <strong>test</strong>.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the port is in use, wait until it is idle before <strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT Incompatible configuration administered on trunk group screen.<br />

1. Look at the Trunk Group administration form <strong>and</strong> see whether the<br />

trunk is incoming only, port 24 on a DS1 Interface with common<br />

control chel signaling, or an automatic CO type such as FX. Under<br />

any of these conditions, this is a normal abort <strong>and</strong> can be ignored.<br />

1018 ABORT Test is disabled by administration. Determine why the <strong>test</strong> has been<br />

disabled before enabling it.<br />

1. To enable the <strong>test</strong>, enter change trunk-group ( is the<br />

number of the trunk group to be <strong>test</strong>ed). Change the Maintenance<br />

Test field on the screen to y.<br />

2. Repeat the <strong>test</strong>.<br />

1354 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />