TDM-Bus Fault Detection <strong>and</strong> Isolation<br />

TDM-bus faults are usually caused by one of the following:<br />

● A defective circuit pack connected to the backplane<br />

● Bent pins on the backplane<br />

TDM-BUS (TDM Bus)<br />

● Defective bus cables or terminators<br />

It is possible that a circuit pack can cause a TDM-bus fault <strong>and</strong> still exhibit trouble-free<br />

operation. For example, insertions of any circuit pack into a slot with TDM bus terminations may<br />

bend the backplane pins <strong>and</strong> short two leads together. Since the TDM bus is a shared resource,<br />

identification of the cause of a TDM-bus fault can be difficult. If a TDM-bus problem is<br />

suspected, run <strong>test</strong> tdm P. If any of the resulting <strong>test</strong>s fail, you must perform a manual TDM<br />

bus isolation procedure to identify the cause of the problem.<br />

WARNING: Since the procedure for isolating TDM-bus faults involves removing circuit packs<br />

<strong>and</strong> possibly disconnecting entire carriers, the procedure is extremely destructive<br />

to the port network that contains the TDM bus being <strong>test</strong>ed. If possible, arrange to<br />

perform this procedure at a time when traffic is minimal.<br />

As circuit packs are removed or entire carriers are disconnected, any active calls terminating on<br />

those circuit packs or carriers will be dropped. If you have any hints about a particular circuit<br />

pack that may be causing the TDM bus problem investigate those before performing this<br />

procedure (for example, look at any circuit packs that were inserted into the PN just before the<br />

TDM bus problem appeared.<br />

When straightening or replacing backplane pins in a carrier that contains a CFY1B Current<br />

Limiter, power to the cabinet must be removed. When straightening or replacing backplane pins<br />

in a carrier that does NOT contain a CFY1B Current Limiter, power to that carrier must be shut<br />

off. Failure to follow this procedure may result in damage to circuit packs <strong>and</strong> power supplies,<br />

<strong>and</strong> can be hazardous to the technician.<br />

Note: Maintenance<br />

Note:<br />

software requires TN748 or TN420 Tone Detector, or TN2182 Tone<br />

Clock, or TN2312 IPSI circuit pack to <strong>test</strong> the TDM bus. Before starting these<br />

procedures, make sure that one of these is installed in the port network being<br />

investigated.<br />