Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Far-End DS1 Converter Circuit Pack<br />

Loopback Test (#788)<br />

This <strong>test</strong> is destructive.<br />

This <strong>test</strong> is executed by the TN574 DS1 Converter circuit pack only. See DS1 Facilities<br />

Connectivity Test (#790) for <strong>test</strong>ing the TN1654 DS1 Converter.<br />

This <strong>test</strong> starts at the specified DS1 converter circuit pack location <strong>and</strong> loops all fiber time slots<br />

at the far edge Fiber Optic Interface of the DS1 converter circuit pack at the other end of the<br />

DS1 converter complex. See Figure 107: Far-End DS1 Converter Loopback Configuration.<br />

The <strong>test</strong> sends digital data through every administered DS1 facility chel. Two different <strong>test</strong><br />

patterns are used: hexadecimal values 55 <strong>and</strong> AA.<br />

For a st<strong>and</strong>ard-, duplex-, or high-reliability system (no PNC duplication), this <strong>test</strong> can only be<br />

executed at the endpoint that is closer to the server relative to the neighbor DS1 converter<br />

circuit pack because of its impact on the system control links, The completion of the <strong>test</strong> is<br />

delayed in this configuration to wait for the recovery of the system control links. For a<br />

critical-reliability system (PNC duplication), this <strong>test</strong> can be executed on any DS1 converter<br />

circuit pack. This <strong>test</strong> runs on the DS1C-BD (DS1 Converter Circuit Pack) maintenance object.<br />

Figure 107: Far-End DS1 Converter Loopback Configuration<br />

Table 450: Far-End DS1 Converter Circuit Pack Loopback Test (#788) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

EI<br />

or<br />

SNI<br />

Metallic or Fiber Connection<br />

DS1CONV<br />

A<br />

Test starts here<br />

Network<br />

Description / Recommendation<br />

DS1CONV<br />

B<br />

Metallic or Fiber Connection<br />

Loops here<br />

2000 ABORT Test timed out while waiting for a response from the circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1502 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

EI<br />

or<br />

SNI<br />

1 of 3