Table 254: TBRI-BD Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

1794 (j) 46094 MIN ON<br />

1795 (j) 46085 MIN ON<br />

2305 (k) 46104 None ON<br />

2306 (k) 46081 None ON<br />

3330 (k) 46083 MIN OFF<br />

3586 (l) MIN OFF<br />

3841 (m) 4096 -<br />

4101<br />

3842 (n) 46095<br />

3843 (o) 46097<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: the circuit pack stopped functioning or was physically removed from the<br />

system. This alarm logs approximately 11 minutes after removing the circuit pack <strong>and</strong>/or the<br />

SAKI Sanity Test (#53) fails.<br />

If the circuit pack is not in the system, insert a circuit pack in the same slot as the <strong>error</strong><br />

indicates. See note (h) for additional information.<br />

c. Error Type 257: transient communication problems between the switch <strong>and</strong> this circuit<br />

pack. Execute <strong>test</strong> board location <strong>and</strong> refer to the repair procedures for the Control<br />

Chel Looparound Test (#52).<br />

d. Error Type 513: on-board hardware failure. Aux Data values correspond to the following<br />

detected <strong>error</strong>s:<br />

Aux Data 4352: External RAM <strong>error</strong><br />

Aux Data 4353: Internal RAM <strong>error</strong><br />

Aux Data 4355: ROM Checksum <strong>error</strong><br />

Aux Data 4357: Instruction set <strong>error</strong><br />

Use busyout board location <strong>and</strong> reset board location to reset the circuit<br />

pack. When reset, the circuit pack executes a set of <strong>test</strong>s to detect the presence of any of<br />

the faults listed above. Detection of one of these <strong>error</strong>s during initialization causes the<br />

circuit pack to lock-up <strong>and</strong> appear insane to the system. See the repair procedure in Note<br />

(b).<br />