Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 394: Expansion Interface Reset Test (#336) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1 FAIL The EI did not successfully reset.<br />

1. If the EI circuit pack is in the PN, the PN’s Maintenance board<br />

may be holding the EI circuit pack reset. Attempt to rectify this<br />

condition by executing <strong>test</strong> maint P long on the<br />

Maintenance board in the same PN.<br />

2. If step 1 was not successful in releasing the EI circuit pack,<br />

temporarily remove the PN’s Maintenance circuit pack.<br />

3. Repeat reset board location.<br />

4. If reset continues to fail, replace circuit pack.<br />

5. Insert PN’s Maintenance circuit pack if it was removed.<br />

2 FAIL The EI circuit pack was successfully reset, but it did not begin running<br />

after the reset.<br />

1. If the EI circuit pack is in the PN, temporarily remove the PN’s<br />

Maintenance circuit pack.<br />

2. Enter reset board location.<br />

3. Reinsert the PN’s Maintenance circuit pack if it was removed.<br />

1360 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />