Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 337: Loss of Signal Alarm Inquiry Test (#138) 7 of 7<br />

Error<br />

Code<br />

1322 FAIL No 5-Volt power detected from the DS1/UDS1 circuit pack to the CSU<br />

module or the Sync Splitter. The problem is probably due to an open fuse<br />

on the DS1/UDS1 board or to a faulty ICSU/Sync Splitter.<br />

Note: Do not immediately swap a DS1/UDS1 board as this may blow the<br />

fuse on the new board.<br />

1. Remove the DS1/UDS1 circuit pack from the system <strong>and</strong> reinsert.<br />

2. Run the <strong>test</strong> again once the circuit pack has finished its reset.<br />

3. If the <strong>test</strong> continues to fail with this Error Code, then replace the<br />

DS1/UDS1 circuit pack <strong>and</strong> run the <strong>test</strong> again.<br />

4. If the <strong>test</strong> continues to fail with this Error Code, the problem could be<br />

in the I/O cable between the backplane <strong>and</strong> the CSU module/Sync<br />

Splitter.<br />

1323 FAIL A service-affecting CSU module/Sync Splitter audit failure was detected<br />

by the DS1/UDS1 circuit pack. Every administered port on the DS1/UDS1<br />

circuit pack is affected, <strong>and</strong> the system will place the ports into the<br />

out-of-service state.<br />

1. Replace the CSU module or the Sync Splitter.<br />

1324 FAIL A non-service-affecting CSU module/Sync Splitter audit failure was<br />

detected by the DS1/UDS1 circuit pack. No ports should be affected. No<br />

immediate action is required. These <strong>error</strong>s indicate that the CSU module/<br />

Sync Splitter hardware may have a problem, <strong>and</strong> that it should be replaced<br />

when practical to avoid further deterioration.<br />

1400<br />

1401<br />

Test<br />

Result<br />

FAIL Echo Canceller function failed. This could be a hardware problem on the<br />

board.<br />

1. Reset the circuit pack.<br />

2. Re<strong>test</strong> the circuit pack.<br />

3. If Test 138 still fails, replace the board.<br />

PASS DS1 signal is present <strong>and</strong> the physical link is healthy. For DS1-BD <strong>and</strong><br />

UDS1-BD, no Integrated CSU/Sync Splitter <strong>error</strong>s or echo cancellation<br />

<strong>error</strong>s have been detected.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

1244 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

7 of 7