Table 270: TONE-PT Error Log Entries 2 of 2<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: A failure in the tone generation facility on the indicated circuit pack has been<br />

detected. Replace the circuit pack. See Replacing the IPSI or Tone-Clock Circuit Pack.<br />

c. Error Type 18: the IPSI or Tone-Clock circuit pack has been made unavailable using<br />

busyout tone-clock location. It only applies to systems which have the high- or<br />

critical-reliability option administered, because only a st<strong>and</strong>by Tone-Clock circuit may be<br />

made busy by that comm<strong>and</strong>. To resolve this <strong>error</strong>, execute release tone-clock<br />

location for the alarmed circuit pack.<br />

Note: IPSI<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

130 (d) MIN ON <strong>test</strong> tone-clock<br />

location<br />

257 (e)(g) 17667 MIN ON<br />

513 (f)(g) 17666 Tone Generator Audit/<br />

Update (#41)<br />

769 (h) Tone Generator<br />

Transmission Test (#40)<br />

1025 (i) Tone Generator Crosstalk<br />

(#90)<br />

1281 (j) Any Tone Generator Audit/<br />

Update (#41)<br />

MIN ON <strong>test</strong> tone-clock<br />

location r 3<br />

MAJ<br />

MIN2<br />

MAJ<br />

MIN2<br />

On/Off<br />

Board<br />

1. IPSI circuit packs require the location qualifier; Tone-Clock circuit packs do not.<br />

Note:<br />

circuit packs require the location qualifier; Tone-Clock circuit packs do<br />

not.<br />

d. Error Type 130: the circuit pack has been removed or has been insane for more than<br />

11-minutes. To clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

e. Error Type 257: the tone generation facility is having problems verifying that tones have<br />

been connected as requested<br />

f. Error Type 513: The tone generation facility may or may not be able to generate tones.<br />

1012 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended<br />

Action<br />

ON <strong>test</strong> tone-clock<br />

location long<br />

ON <strong>test</strong> tone-clock<br />

location long<br />

MIN OFF <strong>test</strong> tone-clock<br />

location r 3<br />

2. MAJOR alarm if the alarmed IPSI or Tone-Clock circuit pack is not duplicated; MINOR if it is duplicated<br />