Table 358: Digital Looparound Test (#171) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Digital Looparound Test (#171)<br />

1180 ABORT There is no Maintenance/Test circuit pack digital port available for <strong>test</strong>ing.<br />

1. Check if the Maintenance/Test digital ports are present. Enter<br />

list config. Ports 02 <strong>and</strong> 03 should be displayed.<br />

2. If the digital ports 02 <strong>and</strong> 03 on the Maintenance/ Test circuit pack<br />

are not present, see M/T-BD (Maintenance/Test Circuit Pack).<br />

3. If the digital ports are present, retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

1181 ABORT No time-slots available to connect digital ports for the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1182 ABORT Internal system <strong>error</strong>. Failed to connect the digital ports with time-slots.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1340 ABORT No Maintenance/Test digital port is currently available to perform this <strong>test</strong>.<br />

1. Enter list config to determine whether the Maintenance/Test<br />

digital ports (ports 02 <strong>and</strong> 03 on the Maintenance/Test circuit pack)<br />

are present in the system. At least one Maintenance/Test circuit<br />

pack must be present in PN 1 of the system. There should be at<br />

least two such ports present. If the ports are present, proceed to<br />

step 2. Otherwise, determine why no ports appear in the list<br />

config display. Refer to M/T-DIG (Maintenance/Test Digital Port)<br />

<strong>and</strong> M/T-BD (Maintenance/Test Circuit Pack).<br />

2. Look for M/T-DIG <strong>error</strong>s in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

3. If the ports are present <strong>and</strong> no <strong>error</strong>s are logged against them, retry<br />

the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort, replace the Maintenance/Test circuit<br />

pack.<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> does not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port (the<br />

display shows that the port is a TTI port) or list config (a “t” is<br />

displayed for the port).<br />

2. If either list config or display port indicates that the port is<br />

not a TTI port, escalate the problem. If both comm<strong>and</strong>s indicate that<br />

the port is a TTI port, no action is necessary.<br />