Table 499: ATM Board Framer Looparound Test (#1260) 3 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ATM Board Framer Looparound Test (#1260)<br />

1141 ABORT The Packet Interface circuit pack is out of service.<br />

1. Resolve any PKT-INT (Packet Interface) problems.<br />

2. Retry the comm<strong>and</strong>.<br />

1144 ABRT The PPN’s packet bus has a major alarm against it. This <strong>test</strong> needs to<br />

use the alarmed PPN’s packet bus.<br />

1. Resolve any PKT-BUS problems.<br />

2. Retry the comm<strong>and</strong>.<br />

1394 ABORT ATM-EI: The ATM-EI board is out of service <strong>and</strong> the <strong>test</strong> cot be run.<br />

1. Run Test #241. If it does not pass, see the repair procedures for<br />

Expansion Interface 2-Way Transmission Test (#241).<br />

ATM-TRK: ATM-TRK circuit pack out of service.<br />

1. Run ATM Board Reset Test #1256. If it does not pass, see the repair<br />

procedures for ATM Board Reset (#1256)<br />

1395 ABORT This <strong>test</strong> cot be run on an ATM-EI circuit pack if it is part of the B-side<br />

PNC <strong>and</strong> duplicated PNC is not enabled.<br />

1. If this <strong>test</strong> needs to run on this ATM-EI circuit pack, enable PNC<br />

duplication with change system-parameters duplication.<br />

2. Prevent the system from doing a PNC interchange with<br />

set PNC lock.<br />

3. Repeat this <strong>test</strong>.<br />

1407 ABORT This <strong>test</strong> cot be run on an ATM-EI board that is on the active PNC<br />

because it cot be busied out. This <strong>error</strong> code indicates that PNC<br />

duplication is enabled.<br />

1. Attempt to perform a PNC interchange with<br />

reset pnc interchange.<br />

2. If the PNC interchange is successful, busyout the original<br />

ATM-Expansion Interface circuit pack with busyout board<br />

location (address of the original ATM-EI board).<br />

3. Retry the comm<strong>and</strong>.<br />

2000 ABORT Response to the <strong>test</strong> was not received in the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

3 of 5<br />