Figure 76: Synchronization Troubleshooting, Fig. 1 of 5<br />

Start Here<br />

Use display <strong>error</strong>s <strong>and</strong> follow the repair procedures for non-slip <strong>error</strong>s<br />

against, SYNC, TDM-CLK, TONE-BD, EXP-INTF, SNI-BD, <strong>and</strong> DS1C-BD<br />

maintenance objects.<br />

Non-Slip <strong>error</strong>s are those NOT listed below:<br />

Board Type Name in Error Log Log Entry (for slips)<br />

DS1 Interface DS1-BD 3073 to 3160<br />

UDS1 Interface UDS1-BD 3073 to 3160<br />

Expansion Interface EXP-INTF 2305<br />

Switch Node Interface SNI-BD 1537<br />

Tone-Clock TDM-CLK 1025<br />

DS1 Converter DS1C-BD 3329<br />

DS1 Facility DS1-FAC 856<br />

Slips<br />

900 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Yes<br />

Is reference a<br />

free-running Tone-Clock<br />

or IPSI?<br />

System is operating<br />

as a timing slave in<br />

the network.<br />

1<br />

Is synchronization<br />

administered <strong>and</strong><br />

enabled?<br />

stat sync<br />

stat sync<br />

Slips on<br />

DS1 facilities?<br />

2<br />

No<br />

No<br />

No<br />

Yes<br />

Yes<br />

Problem is<br />

in switch.<br />

D<br />

Review synchronization plan.<br />

Administer <strong>and</strong> enable<br />

synchronization.<br />

System is operating as<br />

timing master.<br />

To Fig 4<br />

SlipsonsomeDS1<br />

facilities in same PN<br />

as reference?<br />

3<br />

Is the tone clock<br />

or IPSI<br />

designated as the<br />

timing master?<br />

No<br />

Yes<br />

Slips on IPSI or Tone CLK, EIs<br />

SNIs, or non-reference PN DS1s<br />

Use list sync to determine<br />

if the tone clock is<br />

designated as the master.<br />

Use stat sync to determine<br />

if the tone clock was<br />

switched to.<br />

C<br />

No<br />

To Fig 3<br />

Yes<br />

B<br />

A<br />

To Fig 2<br />

To Fig 3<br />

Problems with<br />

reference PN or<br />

synchronization plan