19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

e. Error Type 2817 Aux Data 57393 is an inline <strong>error</strong> that has no specific <strong>test</strong> associated with<br />

it. CO released the trunk at least four minutes after the PBX dropped the call. This <strong>error</strong><br />

code is log only <strong>and</strong> causes no other <strong>test</strong>ing to occur. No alarm is generated. Check for<br />

other <strong>error</strong>s.<br />

f. Error Type 3073 Aux Data 57376 is an inline <strong>error</strong> that has no specific <strong>test</strong> associated with<br />

it. No loop current on incoming call. The incoming destination has already answered <strong>and</strong> no<br />

loop current has been detected. If this is a hard fault, the Dial Tone <strong>test</strong> (#0) <strong>and</strong> every<br />

outgoing call should also fail. Check for other <strong>error</strong>s.<br />

g. Error Type 3585 Aux Data 57424 is an inline <strong>error</strong> that has no specific <strong>test</strong> associated with<br />

it. No loop current on outgoing call. This <strong>error</strong> occurs on an attempt to seize a loop or<br />

ground-start trunk for an outgoing call. An <strong>error</strong> occurs if loop current is not detected or the<br />

caller hangs up before it is detected. Busyout the affected port, <strong>and</strong> run a Long <strong>test</strong>. If the<br />

Dial Tone <strong>test</strong> (#0) passes, ignore this <strong>error</strong>. Release the port.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

340 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

NPE Crosstalk Test (#6) X ND<br />

Dial Tone Test (#0) X ND<br />

CO Port Diagnostic Test (#3) X X ND<br />

Looparound <strong>and</strong> Conference Test (#33) X ND<br />

Port Audit And Update Test (#36) X X ND