Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 403: Expansion Interface Packet Interface Test (#589) 2 of 5<br />

Error<br />

Code<br />

1033<br />

(cont’d)<br />

Test<br />

Result<br />

ABORT<br />

(cont’d)<br />

Description / Recommendation<br />

Center Stage:<br />

If the EI circuit pack under <strong>test</strong> resides in the PN:<br />

None of the EI circuit packs located in the PNs (on the same PNC side)<br />

are in service (for PN EIs see the next case).<br />

5. Enter list fiber-linklist fiber-link to determine whether<br />

any of the PN’s EI circuit packs are administered as endpoints of a<br />

fiber link. If not, then ignore the results of this <strong>test</strong>.<br />

6. Enter list conf for the cabinets <strong>and</strong> carriers where the EI circuit<br />

packs reside in every other PN. If the results returned indicated that<br />

the circuit packs are not recognized by software, they are out of<br />

service for this reason.<br />

7. Enter display <strong>error</strong>s, <strong>and</strong> resolve any EXP-PN (Expansion Port<br />

Network)<strong>error</strong>s. Re-run this <strong>test</strong>.<br />

8. If the <strong>test</strong> continues to abort with this <strong>error</strong> code, reseat the EI circuit<br />

packs (or DS1 converter circuit pack if so equipped) on the PNs.<br />

This will not be destructive since the circuit pack cot be serving as<br />

the Expansion Archangel if it is not in service.<br />

9. Run Test #237 on each of the PN EI circuit packs, <strong>and</strong> check for<br />

EXP-INTF circuit pack Error Type 1281 in the <strong>error</strong> log. If Error Type<br />

is present <strong>and</strong>/or Test #237 does not pass, see repair procedures for<br />

Expansion Interface Neighbor Query Test (#237).<br />

10. Repeat this <strong>test</strong>.<br />

If the EI circuit pack under <strong>test</strong> resides in the PN:<br />

The EI circuit located in the PN is out of service.<br />

1. Run Test #237 on each of the PN EI circuit packs <strong>and</strong> check for<br />

EXP-INTF circuit pack Error Type 1281 in the <strong>error</strong> log. If Error Type<br />

is present <strong>and</strong>/or Test #237 does not pass, see repair procedures for<br />

Expansion Interface Neighbor Query Test (#237).<br />

2. Repeat this <strong>test</strong>.<br />

1139 ABORT The packet bus in the PN where this EI circuit pack resides has a major<br />

alarm against it. This <strong>test</strong> needs to use the alarmed port network’s packet<br />

bus.<br />

1. Enter display alarms <strong>and</strong> resolve any PKT-BUS alarms.<br />

2. Retry the comm<strong>and</strong>.<br />

1378 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />