Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 544: Power Supply Detection Test #(1535) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

1000 ABORT Internal software <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong>.<br />

2. Escalate the problem if the <strong>test</strong> continues to abort.<br />

1035 ABORT The port network is not available.<br />

1. Enter status port-network to verify that the network is not up.<br />

2. Look for alarms against EXP-PN (Expansion Port Network),<br />

EXP-INTF (Expansion Interface Circuit Pack), PKT-INT (Packet<br />

Interface), etc.<br />

3. Use the diagnostic procedures for those MOs to clear the problem.<br />

1987 ABORT The power supply data was not valid.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

2000 ABORT The response to a query was not received in the time allowed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

2029 ABORT There is a problem communicating with the environmental maintenance<br />

firmware.<br />

1. Run <strong>test</strong> maintenance nn<br />

2319 ABORT The EPN is out of range.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong>.<br />