associated port), or when a data module is first connected to an administered port. No<br />

action is necessary.<br />

l. Error Type 2561: the downlink buffer on the circuit pack has overflowed. No action is<br />

necessary.<br />

m. Error Type 2817: a DCP endpoint may have been disconnected.<br />

n. Error Type 1, 769, 1537, 3841: make sure the data module is connected <strong>and</strong> operating<br />

properly. Check for faulty wiring. If necessary, reduce the length of the cable between the<br />

data module <strong>and</strong> the switch to 5000 ft. for 24-gauge wire or 4000 ft. for 24-gauge wire.<br />

If the problem still exists, replace the circuit pack. Once the problem has been resolved,<br />

the alarm will be retired in 60 minutes (90 min. for <strong>error</strong> 1537).<br />

The DA module is not phantom-powered from the port. Thus when it is in linked mode, its<br />

range is limited by the Italtel digital phone’s limit: 0.7 Km (2300 ft.) on 26-gauge wire or 1.8<br />

Km (5900 ft.) on 22-gauge (0.6 mm) wire. If in st<strong>and</strong>-alone mode, it is limited by the<br />

maximum length of loop allowed from the Digital Line Interface (DLI) component: up to 3.5<br />

km (2 miles) on 22-gauge (0.6 mm) wire.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

704 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Long Test<br />

Sequence<br />

Data Module Internal Looparound Test (#175) X ND<br />

GPP NPE Crosstalk Test (#9) X ND<br />

Local Loop Test (#13) X ND<br />

1. D = Destructive; ND = Nondestructive<br />

D/ND 1<br />

Digital Station Audits Test (#17) X X ND