Long IP 2-Way Transmission Test (#1506)<br />

Long IP 2-Way Transmission Test (#1506)<br />

This <strong>test</strong> verifies IP network connectivity between a specified IP Media Processor <strong>and</strong> every<br />

other IP Media Processor in the system. It is an extended version of the Short IP 2-Way<br />

Transmission Test (#1505).<br />

Test #1505 verifies IP voice connectivity in both directions between the specified IP Media<br />

Processor (A) <strong>and</strong> a system chosen destination IP Media Processor (B).<br />

Test #1506 verifies IP voice connectivity in both directions between the specified IP Media<br />

Processor (A) <strong>and</strong> all other IP Media Processor/s (B, C, D, E, ....) that has administered IP<br />

network region connectivity to the IP network region of the source IP Media Processor.<br />

The <strong>test</strong> passes if the source IP Media Processor (A) has 2-way voice connectivity to all other IP<br />

Media Processors. The <strong>test</strong> fails <strong>and</strong> stops immediately if the source IP Media Processor (A) cot<br />

verify 2-way talk path to any destination IP Media Processor. The failure code indicates the port<br />

network that contains the destination Media Processor that could not be reached.<br />

This <strong>test</strong> creates a G.711 audio path between the source IP Media Processor specified in the<br />

comm<strong>and</strong> line <strong>and</strong> a destination IP Media Processor. All destination Media Processors are<br />

chosen from the same IP network region as the source IP Media Processor <strong>and</strong> connected IP<br />

network regions. An audio chel using G.711 is setup between a pair of boards. A 1004-Hz <strong>test</strong><br />

tone is transmitted from the source PN to the destination PN over the G.711 audio chel. The <strong>test</strong><br />

tone is then transmitted from the destination PN to the source PN.<br />

This <strong>test</strong> runs on IPMEDPRO (IP Media Processor).<br />

Table 537: Long IP 2-Way Transmission Test (#1506) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may<br />

be under heavy traffic conditions, or it may have time slots<br />

out-of-service due to TDM-BUS <strong>error</strong>s. A system is considered under<br />

heavy traffic when the Call Processing Occupancy is greater than 50%<br />

or when the System Management <strong>and</strong> the Call Processing<br />

Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />