St<strong>and</strong>by Reference Health Check Test (#651)<br />

St<strong>and</strong>by Reference Health Check Test (#651)<br />

This <strong>test</strong> evaluates the quality of the external synchronization timing source for a st<strong>and</strong>by IPSI<br />

or Tone-Clock circuit pack. Every administered synchronization timing source must be valid for<br />

this <strong>test</strong> to pass. If the Tone-Clock circuit <strong>and</strong> the synchronization timing sources are in different<br />

port networks, the EI circuit packs transport the timing sources to the tone-clock.<br />

Note:<br />

Note: This <strong>test</strong> only runs on the st<strong>and</strong>by IPSI or Tone-Clock circuit pack in a port<br />

network with more than one IPSI or Tone-Clock circuit pack (high- or<br />

critical-reliability option). The Tone-Clock circuit pack must be a TN780 with<br />

firmware 2 or higher, or a TN2182.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

Table 432: St<strong>and</strong>by Reference Health Check Test (#651)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT This <strong>test</strong> may already be running due to a tone-clock installation,<br />

scheduled maintenance, alarm activity, or a dem<strong>and</strong> <strong>test</strong> from another<br />

terminal. This abort can also occur due to an internal system <strong>error</strong>.<br />

1. Try the comm<strong>and</strong> again at 1-minute intervals up to five times.<br />

1184 ABORT This <strong>test</strong> requires an external synchronization source to be administered<br />

(DS1 primary, DS1 primary <strong>and</strong> secondary, or Stratum-3 clock).<br />

1. Administer the external synchronization source <strong>and</strong> retry the <strong>test</strong>.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Try the comm<strong>and</strong> again at 1-minute intervals up to 5 times.<br />