ADX16D-P (16-Port AUDIX Digital Port)<br />

b. Error Type 1 with Aux Data 40987: The user may experience a noisy port or link, due to an<br />

off-board problem that is detected by the port circuit. If so, replace the circuit pack (see<br />

caution at the beginning of this section). Once the problem is resolved, the alarm is retired<br />

after a predetermined time.<br />

c. Error Type 1: At least 15 off-board problems have been detected with the link to the voice<br />

port. When an <strong>error</strong> with the link is detected, an on-board counter is incremented. Also see<br />

Note a above.<br />

d. Error Type 15:An audit request failed - internal <strong>error</strong>.<br />

e. Error Type 18: The port is busied-out by comm<strong>and</strong>. Release the port with release port<br />

location.<br />

f. Error Type 23: The circuit pack is administered but not physically installed. The alarm will<br />

clear when a circuit pack is inserted.<br />

g. Error Type 130: The circuit pack has been removed or has been insane for more than<br />

21-minutes. To clear the <strong>error</strong>, reseat or replace the AUDIX circuit pack (see caution at the<br />

beginning of this section).<br />

h. Error Type 257: Something is interfering with transmission to the voice port. This is usually<br />

an on-board problem <strong>and</strong> can be ignored if there are no user complaints.<br />

i. Error Type 513: AUDIX is not available to the switch, possibly due to a busyout on the<br />

AUDIX system. Refer to DEFINITY® AUDIX Maintenance, 585-300-110.<br />

j. Error Type 1537: There is a problem with the link to the voice port. This can be ignored if<br />

there are no user complaints. If the problem persists, replace the circuit pack (see caution at<br />

the beginning of this section). Once the problem is resolved, the alarm is retired after a<br />

certain period of time.<br />

k. Error Type 2305: The link between the circuit pack <strong>and</strong> the voice port is successfully reset.<br />

No action is necessary.<br />

l. Error Type 3840 with Aux Data 40965: No voice ports are connected to the EMBEDDED<br />

AUDIX circuit pack. No action is required.<br />

m. Error Type 3840 with Aux Data 41029: The message buffer in the circuit pack is full.<br />