Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 316: AC Power Query Test (#78) 2 of 3<br />

Error Code Test<br />

Result<br />

Description / Recommendation<br />

1 FAIL The cabinet is currently without AC power.<br />

Note:<br />

Note: For a J58890CE, skip to Procedures for a<br />

J58890CE.<br />

Procedures for a Global MCC (J58890CH)<br />

1. For a nominal holdover system, if there is no AC power at the<br />

wall outlet, have a qualified electrician restore power to the<br />

outlet. Power should range from 170 to 264 VAC.<br />

2. If there is AC power at the wall outlet, there could be a<br />

problem with the RM0850 rectifiers, BU3200A BIU (battery<br />

interface unit), or battery. Resolve every alarm logged against<br />

POWER, <strong>and</strong> rerun the <strong>test</strong>.<br />

3. If the <strong>test</strong> still fails, the BIU may be defective. Check the BIU.<br />

If the BOD alarm LED is on, replace the BIU. If the BOD LED<br />

is off <strong>and</strong> the BOK LED is on, a PN’s Maintenance circuit pack<br />

may be incorrectly reporting the problem. Resolve every<br />

alarm against these MOs, <strong>and</strong> rerun the <strong>test</strong>.<br />

1184 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />