Table 336: DS1 Tie Trunk Seizure Test (#136) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

DS1 Tie Trunk Seizure Test (#136)<br />

1004 ABORT Far end is seizing the trunk while the <strong>test</strong> is ongoing. A glare situation is<br />

detected.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port. Enter status trunk to determine the<br />

service state of the port. If the port is in use, wait until the port is idle<br />

before <strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT Incompatible configuration administered on Trunk Group form.<br />

1. Verify the following fields on the Trunk Group administration form:<br />

a. Is trunk direction incoming only?<br />

b. Is trunk outgoing type either automatic or immediate-start?<br />

c. Is trunk the 24th port of the DS1 Interface circuit pack or media<br />

module while common control chel signaling is specified?<br />

2. If the trunk has been administered using the above information, this<br />

<strong>test</strong> should abort.<br />

1018 ABORT The <strong>test</strong> was disabled by administration. Determine why the <strong>test</strong> has been<br />

disabled before enabling it.<br />

1. Verify that the Maintenance Test field on the Trunk Group<br />

administration form is n. To enable the <strong>test</strong>, change the trunk<br />

administration <strong>and</strong> enter y in the Maintenance Test field.<br />

2. Repeat the <strong>test</strong>.<br />

1020 ABORT The <strong>test</strong> did not run due to an already existing <strong>error</strong> on the specific port or<br />

due to a more general circuit pack or media module <strong>error</strong>.<br />

1. Examine the <strong>error</strong> log for existing <strong>error</strong>s against this port or the circuit<br />

pack or media module <strong>and</strong> attempt to diagnose the already existing<br />

<strong>error</strong>.<br />

2. Retry the <strong>test</strong>.<br />

1040 ABORT The <strong>test</strong> is invalid for this trunk port because it is administered as an<br />

access endpoint.<br />

1. Enter display port location to verify that this port is<br />

administered as an access endpoint. In this case the <strong>test</strong> should<br />

abort <strong>and</strong> no action is necessary.<br />