Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on EXP-INTF (Expansion Interface Circuit Pack).<br />

Table 377: Expansion Interface Lightwave Transceiver Looparound Test (#242) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic<br />

when the Call Processing Occupancy is greater than 50% or when the<br />

System Management <strong>and</strong> the Call Processing Occupancies together<br />

exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1015 ABORT The EI circuit pack has not been busied out.<br />

1. Busyout the EI circuit pack with busyout board location<br />

2. Enter <strong>test</strong> board location long.<br />

1031 ABORT If the EI circuit pack is in a PN <strong>and</strong> is on the active PNC, <strong>and</strong> is not part of<br />

a PN-to-PN link, this <strong>test</strong> cot be executed. If the lightwave transceiver<br />

looparound is activated, it is impossible to deactivate it.<br />

1. If PNC Duplication is enabled, attempt to make the st<strong>and</strong>by PNC<br />

active with reset pnc interchange.<br />

2. If the PNC Interchange is successful, the Lightwave Transceiver<br />

Looparound <strong>test</strong> may now be executed on the original EI circuit<br />

pack.<br />

1324 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />